A Range of Waste Water and Sewage Package Pump Systems![]() ApplicationsDevelopments where foul drainage by gravity is not possible, including:
Features
DesignAll standard Kingspan Environmental package pump systems are supplied with GRP/polyethylene chambers, pump(s), high-level alarm, pre-set automatic level control, non-return valve, discharge pipe and all connections. Options
Bespoke SystemsKingspan Environmental manufactures pumping chambers of various diameter
and depths, with pumps, guide rails and control equipment
fitted as per the client’s specification.
|
|
||
Product Range |
||
HillMasterThe HillMaster range offers a competitive solution to the
pumping requirements of both domestic and industrial applications.
Often it can be preferable to keep civil work and installation
costs down to a minimum but such economy should not mean any
shortfall in quality.
![]() |
||
HillMaster24The HillMaster24 range has been specifically designed to
meet the requirements of Building Regulations Document H1
Foul Drainage. This regulation recognises the need for pump
stations to have a 24hr storage capacity in case of a disruption
in service (such as a power failure).
|
||
|
||
Effluent PumpsetsA septic tank or treatment system pumpset can be used to disperse settled effluent when a site has a high water table or adverse invert levels. Installed after the septic tank or treatment system and pumping settled effluent up to an inspection chamber, flow to the drainage system then takes place by gravity in the normal way.
|
24hr Storage to Meet Building RegulationsThe Kingspan Environmental HillMaster24 pump station range has been designed in accordance with Building Regulations Document H1 Foul Drainage, page 16. (Pumping Installations) Section 2.39. This states: "Where
foul drainage from a building is to be pumped, the effluent receiving chamber should be sized to contain 24 hour inflow to allow for disruption in service. The minimum daily discharge of foul drainage should be taken as 150 litres per head per day for domestic use. For other types of building, the capacity of the receiving chamber should be based on the calculated daily demand of the water intake for the building. Where only a proportion of the foul sewage is to be pumped, then the capacity should be based pro-rata. In all pumped systems the controls should be so arranged to optimise pump operation. The required 150 litres per head per day volume should reflect the storage volume in the station pump or station and overflow tanks."
|
|
Domestic Sewage PumpsetsIf the main sewer is accessible but at a higher level to (or some distance from) the domestic foul drain, then a domestic sewage pumpset may be used to pump unsettled sewage directly to the main. Whilst single pump units are acceptable for individual houses, it is recommended that twin pumping systems be used for multiple dwellings.
|
||
Surface Water Pumpsets Due to the amount of rainwater that can fall in a short
time period, Surface Water run-off is often the most demanding
of all applications, whether hard-standing or roof areas. |
||
Compact Pump Systems for Wastewater ApplicationsDesigned for rapid installation, the chambers provide simple and speedy dewatering of buildings and areas below the sewer level and are suitable for pumping wastewater in accordance with DIN/EN 12056. Applications
Chambers are suitable for effluent and sewage dependent on pump specification, required distance and lift. Features
Sewage Pump PerformanceChamber A (40mm solids handling)
Effluent Pump Performance
DesignAll systems consist of a polyethylene chamber fitted with a quality pump, float switch, non-return valves, pedestrian duty cover and frame, cover plate and all connections. |
Specification
Installation & OperationThe access neck and cover are universally adjustable in height and can be rotated to allow easy alignment with flooring and landscaping design, independent of the inflow or discharge line directions. A protective cover for the access neck is supplied for use during installation to prevent backfill from damaging the access cover. Access neck extension piece is available as part of the package to facilitate a further 150mm inlet depth if required.
|